Fluke 117 Electrician's Ideal Multimeter With Non-Contact Voltage

  • PRODUCT NAME:

  • Fluke 117 Electrician's Ideal Multimeter With Non-Contact Voltage

  • ART NO:

  • Fluke 117

  • Description:

  • The Fluke 117 Digital Multimeter includes integrated non-contact voltage detection to help get the job done faster. Designed by electricians and engineered by Fluke, Fluke 117 is a compact True-RMS meter for demanding applications like commercial buildings, hospitals, and schools. With its integrated non-contact voltage detection, Auto Volts and LoZ functions that help prevent false readings caused by ghost voltage, the Fluke 117 is a great choice for electricians. In fact, users around the world have said their 117 is an investment inaccuracy. The Fluke 117 provides Min/Max/Average readings and measures frequency and capacitance. Plus, its easy-to-use interface can save you time and enable you to move from job to job more quickly.
    Features: 
    • 1. Accurate, easy-to-use multimeter with integrated VoltAlert™
    •     technology for non-contact voltage detection.
    • 2. Features AutoVolt automatic AC/DC voltage selection.
    • 3. It provides low input impedance to help prevent false readings due
    •      to ghost voltage.
    • 4. Presents a large white LED backlight for working in poorly lit areas.
    • 5. Features True RMS capabilities for accurate measurements on
    •     non-linear loads.
    Specifications: Fluke 117 Electrician's Multimeter with Non-Contact Voltage
    Specifications:
    Maximum voltage between any terminal and earth ground
    600 V
    Safety
    IEC 61010-1: Pollution Degree 2
    IEC 61010-2-033: CAT III 600V
    Fuse for A input
    11 A, 1000 V FAST Fuse (Fluke PN 803293)
    Display
    Digital: 6,000 counts, updates 4 per second
    Bar graph
    33 segments, updates 32 per second
    Operating temperature
    -10°C to +50°C
    Storage temperature
    -40°C to +60°C
    Battery type
    9 volt Alkaline, IEC 6LR61
    Battery life
    400 hours typical, without backlight
    Accuracy Specifications
    DC millivolts
    Range/resolution
    600.0 mV / 0.1 mV
    Accuracy
    ±([% of reading] + [counts]): 0.5% + 2
    DC volts
    Range/resolution
    6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.00 V / 0.1 V
    Accuracy
    ±([% of reading] + [counts]): 0.5% + 2
    Auto volts
    Range/resolution
    600.0 V / 0.1 V
    Accuracy
    2.0% + 3 (DC, 45 Hz to 500 Hz)
    4.0% + 3 (500 Hz to 1 kHz)
    AC millivolts¹ True RMS
    Range/resolution
    600.0 mV / 0.1 mV
    Accuracy
    1.0% + 3 (DC, 45 Hz to 500 Hz)
    2.0% + 3 (500 Hz to 1 kHz)
    AC volts¹ True RMS
    Range/resolution
    6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.0 V / 0.1 V
    Accuracy
    1.0% + 3 (DC, 45 Hz to 500 Hz)
    2.0% + 3 (500 Hz to 1 kHz)
    Continuity
    Range/resolution
    600 Ω / 1 Ω
    Accuracy
    Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of
    500 μs or longer.
    Ohms
    Range/resolution
    600.0 Ω / 0.1 Ω
    6.000 kΩ / 0.001 kΩ
    60.00 kΩ / 0.01 kΩ
    600.0 kΩ / 0.1 kΩ
    6.000 MΩ / 0.001 MΩ
    Accuracy
    0.9% + 1
    Range/resolution
    40.00 MΩ / 0.01 MΩ
    Accuracy
    5% + 2
    Diode test
    Range/resolution
    2.00 V / 0.001 V
    Accuracy
    0.9% + 2
    Capacitance
    Range/resolution
    1000 nF / 1 nF
    10.00 μF / 0.01 μF
    100.0 μF / 0.1 μF
    9999 μF / 1 μF
    100 μF to 1000 μF
    Accuracy
    1.9% + 2
    Range/resolution
    > 1000 μF
    Accuracy
    5% + 20%
    Lo-Z capacitance
    Range
    1 nF to 500 μF
    Accuracy
    10% + 2 typical
    AC amps True RMS (45 Hz to 500 Hz)
    Range/resolution
    6.000 A / 0.001 A
    10.00 A / 0.01 A
    Accuracy
    1.5% + 3
    20 A continuous overload for 30 seconds max
    DC amps
    Range/resolution
    6.000 A / 0.001 A   10.00 A / 0.01 A
    Accuracy
    1.0% + 3
    20 A continuous overload for 30 seconds max
    Hz (V or A input)²
    Range/resolution
    99.99 Hz / 0.01 Hz
    999.9 Hz / 0.1 Hz
    9.999 kHz / 0.001 Hz
    50.00 kHz / 0.01 Hz
    Accuracy
    0.1% + 2
    1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
    2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
    2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
    2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.
    Mechanical and General Specifications:
    Size
    167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
    Weight
    550 g