Features:
The LCD display with automatic polarity indication.
Data-hold function.
AC and DC voltage measurements up to max. 600 V
AC current measurement up to max. 1000 A
Max. Ø for conductor: 30 mm
Resistance measurements: max. 40 Mohm
Frequency measurements: max. 10MHz
Temperature measurements: -50°C to 1,000°C
Diode test, continuity test, and backlight
K-type thermocouple measuring range: from -20°C to 1000°C
Optional probes (not incl.): SONDE890: TEMPERATURE PROBE FOR DVM890, SONDE8264
Duty cycle measurements: 0.5 to 99% @ pulse width of 100µs to 100ms
Capacitance measurement: max. 100µF
Safety: indoor use only (overvoltage Cat. II 600V)
Important safety information
Specifications:
DC voltage: 0.4/4/40/400/600V
Basic accuracy: ±(1.5% of rdg + 3 digits) / ±(0.8% of rdg + 3 digits) for 0.4V range / ±(2.0% of rdg + 3 digits) for 600V range.
Input impedance: 7.8Mohm
Maximum input: 600V
AC voltage: 0.4/4/40/400/600V
Basic accuracy: ±(1.8% of rdg + 5 digits) / ±(0.8% of rdg + 20 digits) for 0.4V range / ±(2.5% of rdg + 5 digits) for 600V range.
Input impedance: 7.8Mohm
Frequency range: 50-60Hz
Maximum input: 600V
DC current: -
Basic accuracy: -
Overload protection: -
AC current: 40/400/1000A (max. line voltage 240V)
Basic accuracy: ±(2.5% of rdg + 10 digits) for 40A range / ±(2.5% of rdg + 5 digits) for 400A range / ±(3.0% of rdg + 4 digits) for 1000A range.
Overload protection: -
Resistance: 400/4K/40K/400K/4M/40M
Basic accuracy: ±(1.0% of rdg + 4 digits) for 400ohm range / ±(1.5% of rdg + 2 digits) for 4K~400K range / ±(2.5% of rdg + 3 digits) for 4M range / ±(3.5% of rdg + 5 digits) for 40M range.
Overload protection: 15s max. 250V (all ranges)
Capacitance: 40n/400n/4µ/40µ/100µF
Accuracy: ±(5.0% of rdg + 100 digits) for 40nF range / ±(3.0% of rdg + 5 digits) for 400nF range / ±(3.5% of rdg + 5 digits) for 4µ~40µF range / ±(5.0% of rdg + 5 digits) for 100µF range.
Inductance: -
Accuracy: -
Basic accuracy: ±(1.2% of rdg + 2 digits) / ±(1.5% of rdg + 5 digits) for 5Hz range / ±(1.5% of rdg + 10 digits) for 5MHz~10MHz range
Overload protection: 15s max. 250V (all ranges)
Temperature: -50°C-1,000°C
Basic accuracy: ±(3.0% of rdg + 5°C)